NDT methods are selected for the material, geometry, expected discontinuity and inspection objective.
Surface examination
- Visual Testing (VT), Liquid Penetrant Testing (PT) and Magnetic Particle Testing (MT).
Internal examination
- Ultrasonic Testing (UT) and Radiographic Testing (RT) where appropriate and authorised.
Condition monitoring
- Ultrasonic thickness gauging for pipework, tanks and accessible components.
Controlled execution
- Approved procedures, qualified personnel, verified equipment, defined test locations and recorded limitations.
Client deliverables
- NDT reports showing method, location, findings, coverage and applicable acceptance criteria.